DICE products prevent undissolved water molecules from freezing in jet fuel, which would result in blockage of fuel lines and possibly engine failure. Meets U.S. Military specifications MIL-DTL-85470B and ASTM STANDARD D4171.
Pure DIETHYLENE GLYCOL MONOMETHYL ETHER, “carbitol”. DICE Flash 190 is the identical chemical formulation utilized by the United States Air Force turbine fleet. This chemical replaces ethylene glycol monomethyl ether as a less toxic and non-hazardous fuel system icing inhibitor.
The DICE brand is the number one Fuel System Icing Inhibitor sold in the United States.This chemical is the standard of excellence for anti-icers in aircraft fuel systems.
For Peak Aviation Performance.
DICE FLASH 190 FUEL SYSTEM ICING INHIBITOR.
- For Control of Fuel System Icing in Aviation Turbine Fuels
- 100% Diethylene Glycol Monomethyl Ether
- Use with Fuel Flow 30-45 GPM
Technical Grade For Industrial Use Only. Recommended Concentration: 0,10% minimum by volume; 0,15% maximum by volume. Contents Treat: 105-155 Gallons of Fuel. CAS NO. 111-77-3. PART NO. D-F190-20. Meets Military Specification MIL-I-85470 A, MIL-DTL85470B and ASTM STANDARD D 4171.
WARNING: TO BE USED ONLY AS AN ANTI-ICING ADDITIVE FOR JET TURBINE ENGINE FUELS. KEEP OUT OF REACH OF CHILDREN. HARMFUL IF INHALED, SWALLOWED, OR ABSORBED BY SKIN. COMBUSTIBLE, READ WARNING LABEL ON BACK OF CAN.
NET WT. 1 LB. 4 OZ (567 g)
WARNING: TO BE USED ONLY AS AN ANTI-ICING ADDITIVE FOR JET TURBINE ENGINE FUELS
DICE FLASH 190
USE CAN UPRIGHT
WARNING: USE WITH ADEQUATE VENTILATION. AVOID BREATHING VAPORS.
Contents under pressure. Do not puncture. Do not store near heat, sparks, or open flame. Exposure to temperatures above 130°F (54,5°C) may cause bursting. Avoid contact with eyes, skin and clothing. Wear face shield or goggles and solvent resistant gloves when handling. Ifsprayed in eyes, flush with large amounts of water. Get medical attention if irritation persists.
FOR USE IN ENCLOSED SYSTEMS ONLY.
REFER TO ADVICE OF AIRCRAFT OR ENGINE MANUFACTURER FOR THE SUITABILITY OF USE: Instructions provided in aircraft and engine operating manuals regarding the use of manufacturer recommended fuel system icing preventative measures must be carefully followed. When used as directed the contents of this can will provide the recommended concentrations of 0,10% by volume minimum to 0,15% by volume maximum. Contents are adequate for a minimum of 105 gallons and a maximum of 155 gallons of fuel to fall within concentration range.
DIRECTION FOR USE
1. Remove actuator cap from top of can.
2. Carefully press valve button (attached to tube and clip assembly) into valve on top of can.
3. Re-attach actuator cap by positioning onto can. Tubing should be in slot.
4. Place clip with tubing onto fuel nozzle.
5. To start flow, press actuator down completely. To stop flow, tilt actuator to side and return to normal position.
6. Use can upright and start flow of DICE FLASH 190 after refueling begins and stop flow of DICE FLASH 190 a moment before refueling stops.
CAUTION: Assure that DICE FLASH 190 is directed into and blends with flowing fuel from fueling nozzle. Do not allow concentrated DICE FLASH 190 to contact interior of fuel tank or coated surface of aircraft. STORAGE AND DISPOSAL: Store away from sources of heat and direct sunlight. It is your duty to dispose of the chemical materials and/or container(s) in accordance with any applicable federal state, or local laws and regulations regarding disposal.